Step 1
Step 2
Step
3
Step 4
Step 5
|
Calculate attic square footage How: Multiply length of attic (in feet) times width
of attic (in feet) 30’ x 40’ = 1,200 square feet
Calculate
NFA (Net Free Area) needed for this attic by using the “1 in 300” rule How: Divide attic square footage
by 300 1,200 sq. ft. ÷ 300 = 4 square feet of NFA needed
Convert
square feet of NFA to square inches How: Multiply square feet of NFA by 144 4
sq. ft. x 144 = 576 square inches of NFA needed
Split the amount of NFA needed equally
between the intake and the exhaust How: Divide square inches of NFA needed by 2 576
sq. in. ÷ 2 = 288 square inches of NFA needed equally for exhaust & intake
Calculate
# of lineal feet of CobraŽ Exhaust Vent needed How: Divide the square inches of NFA needed at the ridge by the NFA
of the CobraŽ Exhaust Vent (CobraŽ Exhaust Vent has 16.9 sq. inches of NFA per lineal foot) 288
sq. in. ÷ 16.9 = 17 lineal feet
This attic requires seventeen (17) lineal feet of CobraŽ
Exhaust Vent to meet FHA minimum requirements. |
Intake ventilation MUST be at least equal to exhaust ventilation. To determine the number of intake vents
needed, select your vent on page 12, and install enough vents so that their combined NFA is at least 288 square inches.
Remember: Always have a balanced ventilation system. In
no case should the amount of exhaust ventilation exceed the amount of intake ventilation. |